Retrospective cohort study demonstrates 78% six-month primary patency with paclitaxel-coated balloons in hemodialysis patients, indicating safe and durable treatment for fistula stenosis.
Objectives The objective of this clinical investigation is to assess the clinical performance and the safety of the drug-coated balloons, Luminor 18 or Luminor 35, in the treatment of arteriovenous fistula stenosis. Methods LUMIFAV was a retrospective, single-center, non-comparative, observational cohort study of adults (≥18 years) treated with paclitaxel-coated balloons between January 2020 and September 2022. Eligible patients had mature upper extremity arteriovenous fistulas, with de novo or recurrent stenosis successfully predilated to ≤30% residual stenosis. The primary endpoint was target lesion primary patency at 6-month follow-up; other endpoints included adverse device effects, mortality, reintervention, access circuit primary patency, and target lesion/vessel revascularization. Analyses included descriptive statistics and Kaplan-Meier estimates. Results Fifty-four patients (78% male; mean age 74 years) were enrolled in the study. Most lesions were juxta-anastomotic (63%); mean lesion length and diameter were 36.9 mm and 2.2 mm, respectively. Pre-dilation was performed in 96%, and 28% underwent post-dilatation. The target lesion primary patency rate at 6 months follow-up was achieved in 78% of patients (38/49; 95% CI [63.0%; 87.8]. No device-related adverse events occurred, and the cumulative mortality rates were 4%, 16%, and 29%, at 30 days, 12 months and 24 months post-index procedure respectively . Main causes were cardiovascular or malignancy. At 30 days, 12 months, and 24 months follow-up the target lesion primary patency rates were 100%, 51% and 26%, respectively; median time to target lesion primary patency failure was 16.2 months. Access circuit primary patency rates were 98%, 54%, 24%, and 15% at 30 days, 6, 12, and 24 months, respectively. Mean time to first reintervention was 6.8 months. Conclusions The Paclitaxel-coated balloons, Luminor 18 and Luminor 35, showed favorable safety and performance for treating arteriovenous fistulas stenosis in hemodialysis patients, supporting their role in maintaining patency without device-related complications and confirming their clinical utility for arteriovenous fistulas management, increasing the delay between re-intervention and maybe, the quality of life for this fragile population.
No takes yet. Share an insight, caveat, or question.
Benjamin Thévenin (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: