Key result
Acurate Neo 2 linked to ~95% VARC-3 device success and better early safety vs Acurate Neo.
Why the study?
Acurate Neo has been linked to significant paravalvular leakage, addressed by Acurate Neo 2 with an active sealing skirt, while midframe under-expansion may also worsen outcomes.
Does the Acurate Neo 2 transcatheter heart valve system improve device success and early safety compared to the Acurate Neo system in patients undergoing TAVI?
Cohort (n=257)
Does the Acurate Neo 2 transcatheter heart valve system improve device success and early safety compared to the Acurate Neo system in patients undergoing TAVI?
Answers are grounded in this paper and cite their sources.
The Acurate Neo 2 valve improves device success and early safety compared to the earlier generation Acurate Neo, though midframe under-expansion remains a risk factor for worse 1-year clinical outcomes.
Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes. Aims We investigated the hemodynamic and clinical outcomes after TAVI with Acurate Neo 2 compared to Acurate Neo and assessed the impact of midframe under‐expansion. Methods Patients who received Acurate Neo ( n = 124) or Acurate Neo 2 ( n = 133) between February 2018 and December 2021 (switch to Acurate Neo 2 in November 2020) were included. The primary outcomes were VARC‐3 defined device success and early safety. Results Device success was higher with Acurate Neo 2 compared with Acurate Neo (94.7% vs. 86.3%, p = 0.020), as was early safety (87.2% vs. 74.2%, p = 0.008). The rate of mild/moderate PVL was significantly lower in Acurate Neo 2. Kaplan−Meier estimated 1‐year survival (Acurate Neo 2: 87.8% vs. Acurate Neo: 89.0, p = 0.930) and freedom from the combined clinical endpoint death, stroke, myocardial infarction, and heart failure rehospitalization at 1 year (Acurate Neo 2: 81.2% vs. Acurate Neo: 79.3%, p = 0.528) were comparable between groups. A long‐term analysis of these endpoints revealed no difference between groups. Midframe under‐expansion occurred in 13.3% and was associated with lower freedom from the combined clinical endpoint at 1 year, irrespective of prosthesis generation. Conclusion Acurate Neo 2 demonstrated significant improvements in device success and early safety compared to Acurate Neo. Midframe under‐expansion occurred with both generations and was associated with worse clinical outcomes within the first year.
No takes yet. Share an insight, caveat, or question.
Crusius et al. (2026) conducted a cohort in Aortic stenosis requiring TAVI (n=257). Acurate Neo 2 vs. Acurate Neo was evaluated on VARC-3 defined device success (p=0.020). TAVI with the Acurate Neo 2 yielded higher VARC-3 defined device success and early safety compared to the Acurate Neo.