Answers are grounded in this paper and cite their sources.
Cohort study reveals predictive accuracy of two-stage indoor nitrogen dioxide modeling in pregnant women, suggesting dynamic infiltration parameters improve personal exposure estimates.
Background Indoor air pollution is a major contributor to personal exposure to air pollution, yet accurately modeling indoor concentrations remains a major challenge in epidemiological studies. This issue is especially relevant since we spend a great portion of our time indoors. Objective To develop a two-stage model to estimate indoor nitrogen dioxide (NO 2 ) concentrations. Methods The study was conducted in the Barcelona Life Study Cohort (2018–2021), a cohort of pregnant individuals in Barcelona, Spain. Indoor and outdoor NO 2 concentrations were measured using passive NO 2 samplers placed in participants’ homes at weeks 12 and 32 of pregnancy. A total of 1695 indoor measurements and 1577 outdoor measurements were collected. In the first stage, we modeled the indoor-outdoor (I/O) NO 2 ratio as a proxy for infiltration using a linear mixed-effects model with repeated measures using 1528 1-week integrated I/O NO 2 measurements. In the second stage, we used a random forest algorithm to estimate weekly indoor NO 2 concentrations covering the full pregnancy period, incorporating the predicted I/O ratios, a previously developed hybrid-model outdoor NO 2 estimate, meteorological data, and home characteristics. Results The I/O NO 2 ratio model showed moderate performance, with a cross-validated R 2 of 0.27 under leave-one-subject-out (generalized model) validation and 0.70 under leave-one-observation-out validation (cohort performance). The indoor NO 2 model achieved a 10-fold cross-validated R 2 of 0.53 and RMSE of 1.28 µg/m 3 . Finally, we estimated indoor NO 2 concentrations for each week of pregnancy using a quantile random forest (QRF) algorithm incorporating uncertainty estimation through prediction intervals. Significance The findings demonstrate that accounting for dynamic infiltration processes and individual-level behaviors improves the estimation of indoor NO 2 exposure. Impact Integrating indoor and outdoor NO 2 measurements in a two-stage modeling framework and combining it with key indoor determinants improves indoor NO 2 estimation.
No takes yet. Share an insight, caveat, or question.
Domínguez et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: