Answers are grounded in this paper and cite their sources.
He and Li beams have been installed and set into operation at the TJ-II stellarator with the aim of measuring electron temperature and density profiles in the edge and scrape-off layer regions of the plasma. The effusive thermal Li beam penetrates up to a normalized effective radius of ρ=0.6–0.7 in typical electron cyclotron heated plasmas. Density profiles deduced from the Li beam are wider than those obtained from extrapolation of the profile measured by Thomson scattering. The He beam is a pulsed supersonic one. Simultaneous detection of three emission lines (667.2, 706.5, and 728.1 nm) is made with a set of three photomultipliers. First He beam measurements of ne and Te in TJ-II are presented and the agreement among results of different plasma edge diagnostics is discussed.
No takes yet. Share an insight, caveat, or question.
Brañas et al. (2001) studied this question.