Key result
Diagnostic cardiac electrophysiology catheters successfully detected spontaneous low-amplitude electrical activity in the bladder and induced local electrical capture in the trigone but not the dome.
Why the study?
Can cardiac electrophysiology catheters be used to map and pace bladder electrical activity in adult female patients undergoing cystoscopy?
Can cardiac electrophysiology catheters be used to map and pace bladder electrical activity in adult female patients undergoing cystoscopy?
Commercially available cardiac electrophysiology equipment can be repurposed to map and pace bladder electrical activity, demonstrating feasibility for urological applications.
Answers are grounded in this paper and cite their sources.
Feasible to record bladder activity with cardiac catheters in humans; leaves open clinical translation for voiding disorders.
AIMS: This is a pilot study to evaluate the feasibility of using diagnostic cardiac electrophysiology catheters for recording intrinsic urinary bladder electrical activity and for electrical pacing capture of bladder tissue. METHODS: During cystoscopy, a curved quadripolar catheter was introduced and contact was made with the right and left halves of the dome and trigone in adult female patients undergoing cystoscopy. Electrical activity was recorded, using a commercially available cardiac electrophysiologic recording system, before and during pacing at 0.5-3.0 Hz. RESULTS: Apparent spontaneous electrical depolarizations were detected in both the trigone and the dome. The amplitude of these depolarizations was in the microVolt range. During pacing, local electrical capture was noted in the trigone, but not in the dome. CONCLUSIONS: Spontaneous low-amplitude electrical activity was detected in the bladder through the use of commercially available cardiac electrophysiology equipment. While these low-level signals could represent noise, the voltage, and morphology resemble detrusor muscle action potentials previously seen in animal studies. Pacing induced local electrical capture in the trigone but not the dome.
No takes yet. Share an insight, caveat, or question.
Kelley et al. (2016) studied Undergoing cystoscopy. Diagnostic cardiac electrophysiology catheters was evaluated on Feasibility of recording intrinsic urinary bladder electrical activity and electrical pacing capture. Diagnostic cardiac electrophysiology catheters successfully detected spontaneous low-amplitude electrical activity in the bladder and induced local electrical capture in the trigone but not the dome.
Synapse has enriched 10 related papers. Consider them for comparative context: