Answers are grounded in this paper and cite their sources.
This brief presents an advanced proportional-derivative (PD) voltage control mechanism for DC/DC boost converters suffering from the parameter and load variations. The proposed controller eliminates the requirement for current feedback by designing the first-order observer estimating the voltage derivative without the use of converter parameters, which corresponds to the first contribution. As another contribution, a specific feedback gain structure for PD-loop and the active damping component guarantees the first-order closed-loop transfer function from the reference to the output voltage by the stable pole-zero cancellation. A prototype bi-directional 3-kW boost converter experimentally validates the closed-loop performance of the proposed technique.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2020) studied this question.