Key result
Functional coagulation analysis using Sonoclot detected early postoperative hypo- and late hypercoagulative phases in all transfusion regimes, correlating better with blood loss than APTT.
Why the study?
Does functional coagulation analysis with Sonoclot better correlate with blood loss and dextran dosage compared to routine coagulation analyses in patients undergoing total hip arthroplasty?
Observational (n=45)
Does functional coagulation analysis with Sonoclot better correlate with blood loss and dextran dosage compared to routine coagulation analyses in patients undergoing total hip arthroplasty?
Functional coagulation analysis using Sonoclot correlates better with blood loss and dextran dosage than routine tests in total hip arthroplasty, suggesting utility for individualizing thromboprophylaxis.
Answers are grounded in this paper and cite their sources.
Sonoclot may better track coagulation shifts than APTT after hip arthroplasty; hypothesis-generating for individualized prophylaxis, pending RCTs.
Functional coagulation analyses like Sonoclot and thromboelastography have not been evaluated during perioperative autotransfusion. We have prospectively studied three different transfusion regimes in 45 patients undergoing total hip arthroplasty. Blood losses were replaced either with heterologous erythrocyte concentrate (group I), intra- and postoperative autotransfusion of blood salvaged with cellsaver technique (group II) or predonated autologous erythrocyte concentrates together with salvaged blood (group III). Routine and functional coagulation analyses with a Sonoclot were performed preoperatively, 6 hours postoperatively (6 h), day 1-5 and 10. An early postoperative hypo- and late postoperative hypercoagulative phase could be detected with Sonoclot signs of platelet function and fibrin deposition in all groups. Sonoclot coagulation analyses better correlated to both blood loss and dextran dosage than APTT and platelet count in the routine coagulation analyses. Functional coagulation analysis has a potential use in individualizing plasmasubstitution and thromboprophylaxis regimes during autotransfusion in THR.
No takes yet. Share an insight, caveat, or question.
Ekbäck et al. (1995) conducted an observational in Total hip arthroplasty (n=45). Autotransfusion regimes (salvaged blood with or without predonated autologous blood) vs. Heterologous erythrocyte concentrate was evaluated on Functional coagulation analysis (Sonoclot signs of platelet function and fibrin deposition). Functional coagulation analysis using Sonoclot detected early postoperative hypo- and late hypercoagulative phases in all transfusion regimes, correlating better with blood loss than APTT.