Answers are grounded in this paper and cite their sources.
We report the results of a spectroscopic ellipsometry (SE) and surface plasmon resonance (SPR) study of mercury vapor adsorption on polycrystalline and (111) gold films. We found that, when Hg adsorbs onto gold films, the change in the ellipsometric parameter delta (Δ) is proportional to the thickness of the adsorbed Hg layer (i.e., Drude approximation). On polycrystalline Au surfaces, Δ increases linearly during the first 15−30 min of Hg exposure, remains constant between 30 and 45 min, and slowly increases beyond 50 min. In contrast, on Au(111) surfaces, Δ increases linearly with Hg exposures up to 30 min but remains constant thereafter. In situ SPR reflectivity curves were measured on ∼50-nm polycrystalline Au films exposed to Hg vapor (∼15 ppm in air). The SPR minimum angle shifts linearly during the first 30 min of Hg exposure. Simulations of the SPR curves predict that the shift in the SPR minimum angle is directly proportional to the mercury coverage. X-ray photoelectron spectroscopy (XPS) revealed that the saturation surface coverage of Hg on Au(111) is 30% lower than that on polycrystalline gold films. The data presented here show that Hg adsorption on atomically flat gold is limited to the surface, whereas Hg diffuses into the bulk on polycrystalline films.
No takes yet. Share an insight, caveat, or question.
Greg Szulczewski (2002) studied this question.