Key result
The signal contacting the surface of a recurrent meniscal tear on MR arthrography may be equal to or less than that of adjacent intraarticular gadolinium contrast material.
Why the study?
Does the signal intensity of recurrent meniscal tears on MR arthrography always equal that of intraarticular contrast material in patients with prior meniscal surgery?
Observational
Does the signal intensity of recurrent meniscal tears on MR arthrography always equal that of intraarticular contrast material in patients with prior meniscal surgery?
The signal intensity of recurrent meniscal tears on MR arthrography is not always equal to intraarticular contrast material, and can be less intense.
Answers are grounded in this paper and cite their sources.
Signal ≤ intraarticular contrast does not exclude recurrent meniscal tear after surgery; leaves open refined diagnostic criteria for post-operative MR arthrography.
OBJECTIVE: Several previous studies reported that the signal contacting the meniscal surface in a recurrent tear on MR arthrography had intensity equal to that of intraarticular contrast material. Because we failed to diagnose recurrent tears using this criterion, we reviewed our knee MR arthrograms in patients who had prior meniscal surgery. CONCLUSION: On knee MR arthrograms, the signal contacting the surface of a recurrent meniscal tear may be equal to or less than that of adjacent intraarticular gadolinium contrast material.
No takes yet. Share an insight, caveat, or question.
Smet et al. (2006) conducted an observational in Recurrent meniscal tears. MR arthrography vs. Intraarticular gadolinium contrast material was evaluated on Signal intensity of recurrent meniscal tear. The signal contacting the surface of a recurrent meniscal tear on MR arthrography may be equal to or less than that of adjacent intraarticular gadolinium contrast material.
Synapse has enriched 10 related papers. Consider them for comparative context: