Answers are grounded in this paper and cite their sources.
A 35 MeV deuteron beam impinging upon a thick Be target is being employed to generate a neutron beam for radiobiological experiments of relevance to later possible fast neutron therapy trials. The primary calibration of the beam has been based upon tissue-equivalent plastic ionization chambers, calibrated in turn with 60 Co gamma -rays. CaF 2 :Mn and 7 LiF (TLD-700) thermoluminescent dosemeters have been employed to determine the gamma -ray dose component in the neutron beam, by a method depending upon the ratio of fast neutron sensitivities of the two phosphors.
No takes yet. Share an insight, caveat, or question.
Attix et al. (1973) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: