In active vibration control of smart structures, the actuator and sensor placement is a key point the control system design. Even the most robust control logics could easily make a structure if the actuators and sensors were not correctly positioned. The objective of this paper to propose an H2 norm approach for the actuator and sensor placement. Unlike most modal 2 norm actuator and sensor placement methodologies, this work aims not only to maximize norms of the controlled modes but also to reduce spillover problems by taking into account residual modes and minimizing their H2 norms. It discusses the optimal actuator and configuration in a finite element model of a square plate fixed on three sides with patch actuators and acceleration sensors. Finally, downstream of the actuator and positioning, IMSC, PPF and NDF controls have been tested and discussed.