Answers are grounded in this paper and cite their sources.
The Airway Scope (AWS-S100, Pentax, Tokyo, Japan) (Fig. 1) is a new video-laryngoscope, currently available in Japan. The device consists of a disposable transparent blade, a 12-cm image channel (with a CCD camera at its tip), and a video screen. The blade is anatomically shaped and a tracheal tube can be attached to the right side. The image channel is inserted into the blade so that the tip is approximately 3 cm proximal to the tip of the blade. The image is displayed on a full colour screen. The device is battery operated. Because of the anatomically shaped blade it is unnecessary to place the patient's head and neck into the Magill (sniffing) position, unlike with a Macintosh laryngoscope. We report four cases of difficult intubation in which the Airway Scope was useful. The Airway Scope. In the first case, a middle-aged woman with a small jaw and thyromental distance of 3.5 cm was scheduled for surgery. The view of the oropharynx was clear (Mallampati grade 2). Anaesthesia was induced and neuromuscular blockade achieved. At laryngoscopy with a size three Macintosh laryngoscope, it was impossible to see the glottis (Cormack and Lehane grade 3); pressure on the neck revealed only a part of the arytenoids. Insertion of the Airway Scope showed a full view of the glottis, and a 7.0-mm tracheal tube attached to the blade was easily advanced into the trachea. In the second case, a middle-aged man was scheduled for lumbar laminoplasty. He had a history of cervical spine disc herniation, and his neck movement was restricted, with Mallampati grade 1. In theatre his head was placed directly on to the trolley and his neck was stabilised. After induction of anaesthesia and neuromuscular blockade, a Macintosh laryngoscope was inserted, but it was impossible to see the glottis. With the Airway Scope a full view of the glottis was seen and trachea was intubated easily. In the third case, a middle-aged man with an unstable neck was scheduled for cervical laminectomy. Tracheal intubation using the Airway Scope was successful at the first attempt, while the head and neck were stabilised. In the final case, a middle-aged man with recurrent regurgitation and vomiting due to multiple antidepressants was scheduled for surgical fixation of a clavicular fracture. Anaesthesia was induced using a rapid sequence technique with cricoid pressure applied. Laryngoscopy did not reveal the glottis, and with pressure, only a part of the right arytenoid was seen. The trachea was easily intubated using the Airway Scope. We feel that the Airway Scope has a role in the patient with a difficult airway. The Airway Scope used by Dr Asai was on a short-term loan from the manufacturer. The model used by Drs Enomoto and Okuda was purchased by their department. No financial support was obtained.
No takes yet. Share an insight, caveat, or question.
Asai et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: