Key result
Centrifugal pumps and heparin-coated circuits did not demonstrate an advantage over roller pumps regarding platelet count and GMP-140 expression during cardiopulmonary bypass.
Why the study?
Does the use of centrifugal pumps or heparin-coated circuits compared to roller pumps improve platelet count and GMP-140 expression in patients undergoing CABG?
RCT (n=61)
Randomly assigned to 3 groups
Does the use of centrifugal pumps or heparin-coated circuits compared to roller pumps improve platelet count and GMP-140 expression in patients undergoing CABG?
The use of centrifugal pumps and heparin-coated circuits during cardiopulmonary bypass for CABG did not demonstrate a clear advantage over roller pumps regarding platelet count and GMP-140 expression.
Answers are grounded in this paper and cite their sources.
Centrifugal pumps and heparin-coated circuits show no platelet advantage over roller pumps; confirms roller pumps remain adequate for CABG cardiopulmonary bypass.
Cardiopulmonary bypass (CPB) is associated with hemostatic disorders, mainly due to platelet function defects. In the present prospective study, platelet count and GMP-140 expression on platelets were investigated to comparatively evaluate the impact of different CPB-circuit systems on platelets. The study included 61 patients undergoing coronary artery bypass grafting, randomly assigned to 3 groups. In group A a roller pump, in group B a centrifugal pump, and in group C a centrifugal pump with a Carmeda heparin-coated CPB circuit was applied. Platelet count and GMP-140 expression were analysed pre, during, and following CPB. None of the tested CPB systems did affect platelet count. The percentage of GMP-140-positive platelets increased slightly early during CPB, whereas it decreased significantly postoperatively; group differences were observed between B and C after protamin administration. An advantage of the use of centrifugal pumps and heparin-coated circuits could not be proven with the present set-up. The results suggest that the benefit of the tested systems might depend on the operative procedure and management.
No takes yet. Share an insight, caveat, or question.
Misoph et al. (1997) conducted an RCT in Coronary artery bypass grafting (n=61). Centrifugal pump with or without heparin-coated circuit vs. Roller pump was evaluated on Platelet count and GMP-140 expression. Centrifugal pumps and heparin-coated circuits did not demonstrate an advantage over roller pumps regarding platelet count and GMP-140 expression during cardiopulmonary bypass.