Key result
Helical CT with and without multiplanar reconstructions achieved 92% diagnostic accuracy for thoracic aortic disease and predicted the need for hypothermic circulatory arrest in 94% of cases.
Why the study?
Does helical CT with multiplanar reconstructions accurately diagnose thoracic aortic disease and predict the need for hypothermic circulatory arrest compared to surgical findings?
Observational (n=49)
Does helical CT with multiplanar reconstructions accurately diagnose thoracic aortic disease and predict the need for hypothermic circulatory arrest compared to surgical findings?
Helical CT is highly accurate for differentiating thoracic aortic diseases and predicting the need for intraoperative hypothermic circulatory arrest.
Answers are grounded in this paper and cite their sources.
May inform preoperative planning in thoracic aortic disease; leaves open need for prospective validation before practice change.
PURPOSE: To assess the accuracy of helical computed tomography (CT) in differentiating different types of thoracic aortic disease, to determine the incremental value of multiplanar reconstructions, and to determine if helical CT could help to reliably predict the need for intraoperative hypothermic circulatory arrest. MATERIALS AND METHODS: Forty-nine patients underwent pre-operative helical CT with multiplanar reconstructions. Images were reviewed for type and location of pathologic lesions and for features that indicated the need for hypothermic circulatory arrest. The incremental yield of multiplanar reconstructions compared with that of axial images was assessed. Imaging findings were compared with surgical findings. RESULTS: The types of lesions present in the patients included 36 aneurysms (three were ruptured), six penetrating ulcers, five dissections, and two pseudoaneurysms. The accuracy of diagnosis was 92% (45 of 49 patients) with the use of CT (both with and without multiplanar reconstruction). The necessity of hypothermic circulatory arrest was successfully predicted in 94% (45 of 48 patients) of cases. CONCLUSION: Helical CT, both with and without the use of multiplanar reconstruction, enabled highly accurate differentiation among diseases of the thoracic aorta and prediction of the need for hypothermic circulatory arrest.
No takes yet. Share an insight, caveat, or question.
Quint et al. (1996) conducted an observational in Thoracic aortic disease (n=49). Helical CT with multiplanar reconstructions vs. Surgical findings was evaluated on Accuracy of diagnosis. Helical CT with and without multiplanar reconstructions achieved 92% diagnostic accuracy for thoracic aortic disease and predicted the need for hypothermic circulatory arrest in 94% of cases.
Synapse has enriched 10 related papers. Consider them for comparative context: