Answers are grounded in this paper and cite their sources.
An 11-year-old male was admitted to our hospital with the acute exacerbation of chronic heart failure. A peripherally inserted central catheter (PICC) was inserted from the left forearm. Ten days after its insertion, the withdrawal of PICC was attempted because of occlusion. However, it was not possible to remove PICC because a fibrin sheath had attached around its tip. A color Doppler and probe compression technique revealed the presence of a fibrin sheath, which could not be detected by gray-scale (real-time B-mode) ultrasonography. This case demonstrated that the color Doppler and probe compression technique is useful for detecting a fibrin sheath.
No takes yet. Share an insight, caveat, or question.
Mogi et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: