Key result
Diabetes mellitus did not significantly affect the risk of appropriate implantable cardioverter defibrillator therapy (HR 1.07) compared to non-diabetic patients, despite a 31% increased risk for death or cardiac hospitalization.
Why the study?
Does diabetes mellitus affect the risk of appropriate or inappropriate ICD therapy and mortality or hospitalization in patients with an ICD or CRT-D?
Cohort (n=2,110)
Yes
Does diabetes mellitus affect the risk of appropriate or inappropriate ICD therapy and mortality or hospitalization in patients with an ICD or CRT-D?
Hazard Ratio: 1.07 (95% CI 0.78–1.47)
Absolute Event Rate: 12% vs 13%
p-value: p=0.694
In patients with an ICD or CRT-D, diabetes mellitus is associated with increased mortality and heart failure hospitalizations but does not increase the risk of appropriate or inappropriate device therapies.
Highlights need for vigilant HF monitoring in diabetic ICD patients; leaves open whether glycemic control modifies arrhythmic risk.
AIMS: There are limited data regarding the effect of diabetes mellitus (DM) on the risks of both appropriate and inappropriate implantable cardioverter defibrillator (ICD) therapy. The present study was designed to compare the outcome of appropriate and inappropriate ICD therapy in patients with or without DM. METHODS AND RESULTS: The risk of a first appropriate ICD therapy for ventricular tachyarrhythmias (including anti tachycardia pacing and shock) was compared between 764 DM and 1346 non-DM patients enrolled in the national Israeli ICD registry. We also compared the risks of inappropriate ICD therapy, and death or cardiac hospitalization between diabetic and non-diabetic patients. Diabetic patients were older, were more likely to have ischemic cardiomyopathy, lower ejection fraction, atrial fibrillation, and other co-morbidities. The 3-year cumulative incidence of appropriate ICD therapy was similar in the DM and non-DM groups (12 and 13%, respectively, p = 0.983). Multivariate analysis showed that DM did not affect the risk of appropriate ICD therapy (HR = 1.07, 95% CI 0.78-1.47, p = 0.694) or inappropriate therapy (HR = 0.72, 95% CI 0.42-1.23, p = 0.232). However, DM was associated with a 31% increased risk for death or cardiac hospitalization (p = 0.005). Results were similar in subgroup analyses including ICD and defibrillators with cardiac resynchronization therapy function recipients, primary or secondary prevention indication for an ICD. CONCLUSIONS: Despite a significant excess of cardiac hospitalizations and mortality in the diabetic population, there was no difference in the rate of ICD treatments, suggesting that the outcome difference is not related to arrhythmias.
No takes yet. Share an insight, caveat, or question.
Steiner et al. (2016) conducted a cohort in Patients with an implantable cardioverter defibrillator (ICD) or CRT-D (n=2,110). Diabetes mellitus vs. Non-diabetic patients was evaluated on Appropriate ICD therapy (HR 1.07, 95% CI 0.78-1.47, p=0.694). Diabetes mellitus did not significantly affect the risk of appropriate implantable cardioverter defibrillator therapy (HR 1.07) compared to non-diabetic patients, despite a 31% increased risk for death or cardiac hospitalization.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: