Answers are grounded in this paper and cite their sources.
Introduction: Pre-anesthetic assessment involves a series of evaluations for airway management. However, the lack of quantitative analysis may limit its reliability. In this study, we propose an optimized YOLO11-Pose framework with a DeBiFormer module for automated, image-based pre-anesthetic assessment. Methods: The proposed model performs single-stage inference to localize clinically relevant facial and hand keypoints associated with mouth opening, thyromental distance, and neck mobility. The framework was evaluated on a dataset collected from Ruijin Hospital under controlled acquisition conditions. Results: Experimental results demonstrated high detection performance. Measurement-based evaluations, including Bland-Altman analysis, pixel-level error, and normalized mean error (NME), indicated reliable agreement with reference annotations. In addition, Mallampati classification was evaluated to assess clinical applicability. The model achieved an accuracy of 77.34% in the four-class setting and improved performance in a clinically motivated binary setting, with an accuracy of 83.99% and a quadratic weighted kappa of 0.65, indicating substantial agreement. Discussion: These results suggest that the proposed method provides robust and clinically meaningful assessment of airway characteristics and may support automated pre-anesthetic evaluation in clinical practice.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: