Key result
The use of a distal embolic protection device during percutaneous coronary intervention for acute myocardial infarction increased the rate of final TIMI 3 flow compared to an aspiration catheter.
Why the study?
Does a distal embolic protection device improve angiographic and tissue-level reperfusion compared to an aspiration catheter during PCI for acute myocardial infarction?
Cohort (n=135)
No
Does a distal embolic protection device improve angiographic and tissue-level reperfusion compared to an aspiration catheter during PCI for acute myocardial infarction?
Distal embolic protection during PCI for acute myocardial infarction significantly improves angiographic tissue-level reperfusion compared to aspiration catheter use.
Answers are grounded in this paper and cite their sources.
May support distal embolic protection in AMI PCI; leaves open randomized confirmation of clinical outcomes.
BACKGROUND: The beneficial effect of percutaneous coronary intervention (PCI) using stents for acute myocardial infarction (AMI) has already been demonstrated, but there is the problem that mechanical microvascular occlusion can occur because of thrombus/atheroma embolization when the PCI was performed. The aim of the present study was to retrospectively test and compare the effects of an aspiration catheter or distal embolic protection with a distal occlusion balloon catheter to prevent peripheral vascular embolization. METHODS AND RESULTS: The subjects consisted of 135 patients who underwent PCI with stenting within 12 h of the onset of chest pain caused by their first AMI. They were divided into 2 groups; the aspiration group, consisted of 81 consecutively seen patients who underwent aspiration catheter treatment between January 2001 and May 2002, and the distal protection group was the next group of 54 consecutively seen patients treated with a distal protection device between June 2002 and February 2003. The results were as follows. Thrombolysis in Myocardial Infarction (TIMI) score of 3 was obtained significantly more frequently in the distal protection group (94.4%) than in the aspiration group (79.0%). Additionally, the intensity of the cardiac muscle stain (blush score) was evaluated on coronary angiography and the rate of cases showing a blush score of 3, which indicates favorable blood perfusion at the tissue level, in the distal protection group (56.6%) was significantly greater than in the aspiration group (33.3%, p<0.01). The time to peak blood concentration of creatinine kinase was also significantly shorter in the distal protection group. CONCLUSIONS: The distal embolism protection method is superior to the aspiration method for prevention of embolization after PCI with stenting for AMI, in terms of tissue level reperfusion in myocardial recanalization therapy.
No takes yet. Share an insight, caveat, or question.
Taguchi et al. (2004) conducted a cohort in Acute Myocardial Infarction (n=135). Distal embolic protection device (PercuSurge GuardWire Plus) vs. Aspiration catheter (Rescue Aspiration Catheter) was evaluated on Final TIMI grade 3 flow (p=<0.03). The use of a distal embolic protection device during percutaneous coronary intervention for acute myocardial infarction increased the rate of final TIMI 3 flow compared to an aspiration catheter.
Synapse has enriched 10 related papers. Consider them for comparative context: