Key result
TAVR with embolic protection in the West links to ~62% higher stroke/TIA odds vs Northeast.
Why the study?
This study aimed to evaluate the utilization and outcomes of cerebral embolic protection during TAVR across USA regions.
Does geographic region within the United States affect the utilization and in-hospital clinical outcomes (stroke, TIA, mortality, length of stay, and hospital charges) of cerebral embolic protection during transcatheter aortic valve replacement?
Cohort (n=11,630)
Yes
Does geographic region within the United States affect the utilization and in-hospital clinical outcomes (stroke, TIA, mortality, length of stay, and hospital charges) of cerebral embolic protection during transcatheter aortic valve replacement?
This national analysis demonstrates marked US regional disparities in both the adoption of cerebral embolic protection during TAVR (ranging from 3.1% in the South to 11.3% in the Northeast) and in-hospital stroke and mortality outcomes among CEP-treated patients.
Answers are grounded in this paper and cite their sources.
Regional disparities in CEP outcomes with TAVR warrant cautious interpretation; leaves open whether unmeasured confounders drive observed differences.
Aim: To evaluate the utilization and outcomes of cerebral embolic protection (CEP) during transcatheter aortic valve replacement (TAVR) by USA region, using discharge data from the National Inpatient Sample (NIS), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality. Patients & methods: All TAVR discharge encounters from June 2017–2019 were included in the analysis. Discharge encounters with bicuspid anatomy were excluded. Regional CEP utilization rates were reported. For TAVR cases performed with the Sentinel CEP device (Boston Scientific, MA, USA), multivariable logistic regression was performed to model regional differences in TAVR outcomes including: stroke, transient ischemic attack (TIA), stroke/TIA combined, and in-hospital all-cause mortality. Generalized linear regression models were used to assess regional differences in length of stay (LOS) and hospital charges. Results: The Northeast had the greatest overall CEP utilization rate (11.3%), followed by the Midwest (11.1%), West (8.7%), then South (3.1%). Compared with the Northeast, the South was associated with a lower risk of stroke (OR: 0.267, 95% CI: 0.106–0.673; p = 0.005), and the West a higher risk of stroke (OR: 1.583, 95% CI: 1.044–2.401; p = 0.031). Compared with the Northeast, the West was associated with a higher risk of stroke/TIA combined (OR: 1.618, 95% CI: 1.107–2.364; p = 0.013). Compared with the Northeast, the Midwest (OR: 4.501, 95% CI: 2.229–9.089; p < 0.001) and West (OR: 5.316, 95% CI: 2.611–10.824; p < 0.001) were associated with a higher risk of in-hospital all-cause mortality. Adjusted charges and LOS were highest in the West. Conclusion: Within the USA, there are regional differences in the utilization and outcomes of CEP use during TAVR. To prevent regional disparities and ensure consistent quality of care in the USA, further research is needed to determine what variable(s) may be responsible for regional differences in TAVR outcomes, with or without CEP.
No takes yet. Share an insight, caveat, or question.
Elisa M Amoroso (2023) conducted a cohort in Aortic valve disease undergoing transcatheter aortic valve replacement (TAVR) with cerebral embolic protection (CEP) (n=11,630). US geographic region (West region vs Northeast region during TAVR with Sentinel cerebral embolic protection) vs. Northeast region was evaluated on In-hospital stroke/transient ischemic attack (TIA) combined (OR 1.618, 95% CI 1.107-2.364, p=0.013). TAVR with cerebral embolic protection in the West region was associated with higher odds of in-hospital stroke/TIA and mortality vs the Northeast.
Synapse has enriched 10 related papers. Consider them for comparative context: