Key result
Multiplex real-time PCR assays showed 86.2%-95.7% sensitivity and 97.2%-99.5% specificity for detecting rotavirus, norovirus, and adenovirus compared to conventional PCR.
Why the study?
Do multiplex real-time PCR assays provide sensitive and specific detection of gastroenteritis-associated viruses compared to conventional RT-PCR/PCR in pediatric patients?
Do multiplex real-time PCR assays provide sensitive and specific detection of gastroenteritis-associated viruses compared to conventional RT-PCR/PCR in pediatric patients?
The developed multiplex real-time PCR assays provide a sensitive and specific method for the rapid simultaneous detection of multiple gastroenteritis-associated viruses in pediatric patients.
Answers are grounded in this paper and cite their sources.
May support rapid multiplex viral testing in pediatric gastroenteritis; leaves open clinical utility pending larger validation studies.
Background: Viral gastroenteritis is one of the most common causes of morbidity and mortality in infants and young children in China. Objectives: To develop a rapid and sensitive real time PCR method capable of detecting several viruses associated with gastroenteritis in pediatric patients simultaneously. Methods: Two multiplex real-time PCR assays, the first targeting the RNA viruses: rotavirus, norovirus and parachovirus and the second the DNA viruses: human adenovirus and human bocavirus 2, were designed and assessed for their specificity and sensitivity. The multiplex assays were evaluated using clinical samples and compared to conventional RT-PCR/PCR. Results The multiplex assays developed in the study were successful in detecting the five target viruses. No cross-reactions with a panel of other human viruses were presented. The assays were sensitive enough to detect as little as one copy of in vitro transcribed target RNA or plasmid DNA in a single reaction. Compared to conventional RT-PCR or PCR, the multiplex assays showed acceptable sensitivity from 86.2% to 95.7% together with high specificity (97.2% to 99.5%) in detecting rotavirus, norovirus and adenovirus. Conclusion: The development of these two multiplex assays should result in significant improvement in the screening of viral pathogens associated with pediatric gastroenteritis in China.
No takes yet. Share an insight, caveat, or question.
Dongmei Chen (2014) studied Viral gastroenteritis. Multiplex real-time PCR assays vs. Conventional RT-PCR/PCR was evaluated on Sensitivity and specificity for detecting rotavirus, norovirus and adenovirus. Multiplex real-time PCR assays showed 86.2%-95.7% sensitivity and 97.2%-99.5% specificity for detecting rotavirus, norovirus, and adenovirus compared to conventional PCR.
Synapse has enriched 10 related papers. Consider them for comparative context: