Answers are grounded in this paper and cite their sources.
In this paper, the open-circuit dc-winding-induced voltage in a wound field switched flux (WFSFs) machines is analyzed. The phenomenon of open-circuit dc-winding-induced voltage is illustrated and the mechanism is explained. Rotor skewing is proposed to reduce the open-circuit dc-winding-induced voltage, and the optimal skewing angle is analytically derived based on the analytically deduced harmonic orders of the open-circuit dc-winding-induced voltage. Finite-element (FE) analyses show that the open-circuit dc-winding-induced voltages in the analyzed 12-stator-pole partitioned stator WFSF machines having 10-, 11-, 13-, and 14-rotor-pole rotors can be effectively reduced by >94%, while the ac-winding phase-fundamental back-EMFs can be maintained by >95%. Twelve/ten-stator/rotor-pole prototypes with skewed and nonskewed rotors are built and tested to verify the analytical and FE results.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: