Finite element analysis shows compromised stability during two-level cervical fusion with fifty percent uncinate resection, suggesting resections exceeding thirty percent need supplemental fixation.
BACKGROUND: The necessity and extent of uncinate process resection (UPR) during anterior cervical discectomy and fusion remains controversial. The Zero-Profile device offers a low-profile alternative to traditional plate-cage systems but its biomechanical stability following various degrees of UPR, particularly in two-level ACDF, has not been clearly established. METHODS: This computational finite element analysis used a validated three-dimensional C2–T1 cervical spine model to simulate Two-Level ACDF (C4–C6) with a Zero-Profile construct under three unilateral uncinate process resection (UPR) conditions (0%, 30%, 50%). No clinical or cadaveric experiments were performed. Under six physiological motions (flexion, extension, left/right lateral bending, left/right axial rotation), we quantified global and segmental range of motion (ROM), adjacent-segment ROM, von Mises stress in the implant, vertebral body and endplate stresses, intradiscal pressure (IDP), and maximum displacement. RESULTS: Unilateral UPR led to a dose-dependent deterioration in biomechanical stability. In the 50% UPR model, the ROM of the C4/5 segment increased by 29.4% in flexion and 16.7% in lateral bending, while adjacent levels (C3/4 and C6/7) also exhibited elevated ROMs, indicating reduced segmental rigidity and increased compensatory motion. Stress on the fixation components rose significantly, with peak screw stress increasing by 47.1% and cage stress by 90.0% under flexion. Endplate stresses also increased, particularly in bending and rotation, with the C5 superior and C6 inferior endplates showing stress increments of 41.5% and 20.3%, respectively. Moreover, IDP at adjacent segments increased with greater UPR extent, reflecting enhanced load transmission to non-fused levels. The maximum construct displacement rose by 50.0% in flexion and 48.8% in axial rotation in the 50% UPR model, underscoring the progressive compromise of structural integrity. In contrast, the 30% UPR model demonstrated only mild changes in motion, stress, and displacement, suggesting that biomechanical performance remained within acceptable limits. CONCLUSIONS: Extensive UPR (≥ 50%) substantially compromises biomechanical stability in two-level ACDF using the ZP fixation, increasing mechanical load on implants and adjacent segments. ZP fixation appears acceptable when UPR is limited to 30%, but caution is warranted when higher resection is required. Surgeons should consider supplemental fixation strategies or alternative systems when extensive UPR is anticipated.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: