Key result
Previous over- or undertreatment, high target INR, and higher warfarin doses were associated with poorer precision of anticoagulant control, which also varied substantially among hospitals.
Why the study?
What factors influence the precision of anticoagulant control using warfarin?
Observational (n=2,207)
Yes
What factors influence the precision of anticoagulant control using warfarin?
Previous poor INR control, high target INR, and higher warfarin doses are key predictors of suboptimal anticoagulant control, highlighting patients needing closer monitoring.
Prior poor control may flag patients for closer monitoring; leaves open whether hospital protocols can enhance precision.
AIM: To determine what factors influence the precision of anticoagulant control using warfarin by examining the computerised records of 2207 patients. METHODS: Records from seven district general hospitals were combined and analysed. The precision of anticoagulant control was taken as the absolute deviation of International Normalised Ratio (INR) from target at the most recent determination. This quantity was examined using univariate and multiple regression analyses. RESULTS: Deviation of INR from target was continuously distributed, almost symmetrically about a mean of zero. The patients' age and sex had little bearing on control. Patients with a high target INR were more likely to be undertreated, and patients taking higher doses of warfarin were more likely to be overtreated. Previous over- or undertreatment were strongly related to poorer current control. The control of treatment varied substantially among the seven hospitals. One possible cause of this variation was the dose adjustment coefficient: the greater the dose adjustment for a given deviation from target INR, the better was the control achieved. CONCLUSION: Several groups of patients were identified whose control was less satisfactory and in whom anticoagulant treatment needs particular scrutiny: these include patients with a record of previous over- or undertreatment, but not elderly patients in general. The variation in control among hospitals is a source of concern that merits further attention to achieve better uniformity of anticoagulant treatment.
No takes yet. Share an insight, caveat, or question.
Britt et al. (1992) conducted an observational in Patients receiving warfarin treatment (n=2,207). Patient and treatment factors (e.g., target INR, dose, previous control) was evaluated on Absolute deviation of International Normalised Ratio (INR) from target at the most recent determination. Previous over- or undertreatment, high target INR, and higher warfarin doses were associated with poorer precision of anticoagulant control, which also varied substantially among hospitals.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: