BACKGROUND: New transparent dressings with chlorhexidine gluconate in the dressing are available. OBJECTIVES: To compare the effectiveness of a new 1-piece occlusive dressing that incorporates chlorhexidine gluconate with that of a dressing plus a chlorhexidine gluconate patch in maintaining the low rate of catheter-related bloodstream infections in the intensive care unit and to evaluate nurses' satisfaction with and cost of the new dressing. METHODS: A quality improvement observational study was done in an adult medical-surgical intensive care unit. All patients with a central venous catheter had initial and/or subsequent dressing changes done with the new dressing. The central catheter bundle elements of the Institute for Healthcare Improvement were followed. Patients were monitored for catheter-related bloodstream infections, and the rate of infection was calculated. RESULTS: During the study period of 1881 device days, the infection rate was 0.051 per 1000 device days, compared with a rate of 0.052 in 2008. Nurses preferred the new dressing. Cost savings were $3807. CONCLUSION: A low rate of catheter-related bloodstream infections can be maintained, nurses' satisfaction achieved, and cost savings realized with the new dressing.