This is the authors' abstract. We don't add key points for this paper.
We investigate the stresses in thin films with sub-millimeter lateral spatial resolution using a dense array of prefabricated cantilever beams prepared by microelectromechanical-system techniques. Stress induced deflection of the cantilever is interrogated by an optical (laser/position sensitive detector) measurement system. Composition spread films are deposited on the cantilever array using a three gun on-axis magnetron cosputtering system. The position dependent composition is inferred using rate calibrations and verified by electron microprobe/energy dispersive spectroscopy. We demonstrate the function of this system using an Fe-Ni-Al composition spread with approximately 1 at. % resolution. This approach allows for measurement of the composition dependence of other electromechanical properties such as the martensitic phase transition temperature of traditional and ferromagnetic shape-memory alloys, as well as the properties of hydrogen storage materials and the magnetic response of magnetostrictive materials.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Woo et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: