Key result
Among 24 surgical novices performing 96 laparoscopic cholecystectomies in a box trainer, 2,895 critical events were observed, of which 36.6% were highly critical.
Why the study?
Uncontrolled instrument movement outside the camera field of view during laparoscopic surgery can cause tissue damage, but the incidence and relevance of such events remain unknown.
Observational (n=24)
No
Surgical novices frequently activate electrosurgical instruments outside the laparoscopic field of view, highlighting a significant risk for inadvertent tissue damage and the need for targeted training.
Answers are grounded in this paper and cite their sources.
High frequency of instrument excursions in novice LC simulations; leaves open real-world incidence and whether targeted training reduces collateral injury risk.
Uncontrolled movement of instruments in laparoscopic surgery can lead to inadvertent tissue damage, particularly when the dissecting or electrosurgical instrument is located outside the field of view of the laparoscopic camera. The incidence and relevance of such events are currently unknown. The present work aims to identify and quantify potentially dangerous situations using the example of laparoscopic cholecystectomy (LC). Twenty-four final year medical students were prompted to each perform four consecutive LC attempts on a well-established box trainer in a surgical training environment following a standardized protocol in a porcine model. The following situation was defined as a critical event (CE): the dissecting instrument was inadvertently located outside the laparoscopic camera’s field of view. Simultaneous activation of the electrosurgical unit was defined as a highly critical event (hCE). Primary endpoint was the incidence of CEs. While performing 96 LCs, 2895 CEs were observed. Of these, 1059 (36.6%) were hCEs. The median number of CEs per LC was 20.5 (range: 1–125; IQR: 33) and the median number of hCEs per LC was 8.0 (range: 0–54, IQR: 10). Mean total operation time was 34.7 min (range: 15.6–62.5 min, IQR: 14.3 min). Our study demonstrates the significance of CEs as a potential risk factor for collateral damage during LC. Further studies are needed to investigate the occurrence of CE in clinical practice, not just for laparoscopic cholecystectomy but also for other procedures. Systematic training of future surgeons as well as technical solutions address this safety issue.
No takes yet. Share an insight, caveat, or question.
Rolinger et al. (2022) conducted an observational in Surgical novices performing laparoscopic cholecystectomy (n=24). Laparoscopic cholecystectomy performance by surgical novices was evaluated on Incidence of critical events (CEs), defined as the dissecting instrument inadvertently located outside the laparoscopic camera's field of view. Among 24 surgical novices performing 96 laparoscopic cholecystectomies in a box trainer, 2,895 critical events were observed, of which 36.6% were highly critical.
Synapse has enriched 10 related papers. Consider them for comparative context: