Answers are grounded in this paper and cite their sources.
Assimilable organic carbon (AOC), residual disinfectant, and temperature were investigated as predictors of biological stability in 18 drinking water distribution systems (DWDSs). Surface water-supplied DWDSs exhibited significantly higher (p < 10–4) AOC concentrations (median = 50 μg/L; range = < LOD to 720 μg/L) compared to groundwater-supplied systems (median = 16 μg/L; range = < LOD to 156 μg/L). AOC levels were significantly higher (p < 10–4) during the summer months (August 2024 to October 2024) in surface water-supplied DWDSs than during the fall (October 2024 to December 2024). In contrast, AOC concentrations in groundwater-supplied DWDSs were similar during the summer and fall. Multivariate statistical analyses showed that residual disinfectant concentration was the strongest predictor of biostability, despite AOC concentrations in some systems being higher than the suggested threshold for biostability (50 μg/L) in disinfected DWDSs. Notably, decreases in AOC concentrations corresponded with increases in bacterial concentrations (measured as 16S rRNA gene copies) in systems where the residual disinfectant concentration was negligible at the distal location. This study, therefore, demonstrates that residual disinfectant concentration is a better predictor of biostability within DWDSs than AOC, even when AOC concentrations are significantly higher than the previously suggested threshold for biostability.
No takes yet. Share an insight, caveat, or question.
Goel et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: