Answers are grounded in this paper and cite their sources.
Systematic studies on the across‐wind dynamic interference effects on two and three tall buildings are presented in this paper. It is found that surrounding and upstream interfering building(s) can significantly affect the across‐wind load on the interfered principal building. Generally speaking, two interfering buildings can cause more adverse dynamic effects on the principal building than a single one does. The results show that the maximum interference factor (IF) among three buildings increases 80% over that between two buildings in terrain category B which has been defined in Chinese load code for design of building structures; a noticeable difference of 29% of IF is also observed in terrain category D. Vortex shedding from the upstream buildings can lead to vortex‐induced resonance, resulting in excessive across‐wind loads on the downstream building. Although interference effects in terrain category D are much smaller than those in exposure category B, the maximum IF is found to be 1·83 in the case of three buildings with the same size in terrain category D and 2·27 in other configurations.