In this work, the ablation dynamics of TiN coating with a ns-pulsed fibre laser in a wide range of pulse durations were studied. Critical time instances within the pulse duration were assessed by reflected pulse analysis. Digital holography was employed to investigate the shock wave expansion dynamics within and beyond the pulse duration. The results depict that the absorption behaviour changes as a function of the pulse rise time. Moreover, planar expansion of the shock wave is observed, which is generally linked to higher machining quality and absence of excessive plasma. The results of the study are interpreted to depict the required characteristics of optimized pulse shapes in the ns-region for improved micromachining performance.
No takes yet. Share an insight, caveat, or question.
Demir et al. (2015) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: