We have developed a sensitive in vitro assay for detecting disease-associated prion aggregates by combining an aggregation-specific enzyme-linked immunosorbent assay (AS-ELISA) with the fluorescent amplification catalyzed by T7 RNA polymerase technique (FACTT). The new assay, named aggregation-specific FACTT (AS-FACTT), is much more sensitive than AS-ELISA and could detect prion aggregates in the brain of mice as early as 7 days after an intraperitoneal inoculation of PrP(Sc). However, AS-FACTT was still unable to detect prion aggregates in blood of infected mice. To further improve the detection limit of AS-FACTT, we added an additional prion amplification step (Am) and developed a third-generation assay, termed Am-A-FACTT. Am-A-FACTT has 100% sensitivity and specificity in detecting disease-associated prion aggregates in blood of infected mice at late but still asymptomatic stages of disease. At a very early stage, Am-A-FACTT had a sensitivity of 50% and a specificity of 100%. Most importantly, Am-A-FACTT also detects prion aggregates in blood of mule deer infected with the agent causing a naturally occurring prion disease, chronic wasting disease. Application of this assay to cattle, sheep, and humans could safeguard food supplies and prevent human contagion.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: