Answers are grounded in this paper and cite their sources.
The local entrainment rate in the initial region of axisymmetric turbulent air jets has been measured by a novel method, which is an adaptation of the ‘porous-wall’ technique used by Ricou & Spalding (1961). The local entrainment rate, which is independent of the nozzle Reynolds number for values greater than 6 × 10 4 , is strongly dependent upon the axial distance. At an axial distance of one nozzle diameter the local entrainment rate is only about one-third of that in the fully developed jet; the entrainment rate increases with increasing axial distance to reach the fully developed value at an axial distance of about thirteen nozzle diameters.
No takes yet. Share an insight, caveat, or question.
Barry Hill (1972) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: