A new laser interferometer for geophysical purposes is being operated in an underground laboratory in central Italy. A simple electro-optical technique has been used to limit the costs. The main characteristics of this instrument are: high sensitivity (Δl/l≈10−12), fast sampling rate (up to 6 kHz), large dynamic range (unbounded in principle), the capability of following strain rates as high as 7×10−5 s-1, and good reliability (two failures in nearly two years).
No takes yet. Share an insight, caveat, or question.
Crescentini et al. (1997) studied this question.