Answers are grounded in this paper and cite their sources.
// Prakash Gangadaran 1 , Xiu Juan Li 1 , Ho Won Lee 1 , Ji Min Oh 1 , Senthilkumar Kalimuthu 1 , Ramya Lakshmi Rajendran 1 , Seung Hyun Son 1 , Se Hwan Baek 1 , Thoudam Debraj Singh 1, 2 , Liya Zhu 1 , Shin Young Jeong 1 , Sang-Woo Lee 1 , Jaetae Lee 1 and Byeong-Cheol Ahn 1 1 Department of Nuclear Medicine, Kyungpook National University School of Medicine and Hospital, Daegu 700-721, Republic of Korea 2 Department of Medical Oncology, All India Institute of Medical Sciences (AIIMS), Ansari Nagar, New Delhi 110029, India Correspondence to: Byeong-Cheol Ahn, email: abc2000@knu.ac.kr Keywords: imaging; extracellular vesicle; bioluminescence; in vivo biodistribution; thyroid cancer Received: February 16, 2017 Accepted: October 28, 2017 Published: November 18, 2017 ABSTRACT In vivo biodistribution and fate of extracellular vesicles (EVs) are still largely unknown and require reliable in vivo tracking techniques. In this study, in vivo bioluminescence imaging (BLI) using Renilla luciferase (Rluc) was developed and applied to monitoring of EVs derived from thyroid cancer (CAL-62 cells) and breast cancer (MDA-MB-231) in nude mice after intravenous administration and was compared with a dye-based labeling method for EV derived from CAL-62 cells. The EVs were successfully labeled with Rluc and visualized by BLI in mice. In vivo distribution of the EVs, as measured by BLI, was consistent with the results of ex vivo organ analysis. EV-CAL-62/Rluc showed strong signals at lung followed by liver, spleen & kidney ( P < 0.05). EV-MDA-MB-231/Rluc showed strong signals at liver followed by lung, spleen & kidney ( P < 0.05). EV-CAL-62/Rluc and EV-MDA-MB-231/Rluc stayed in animal till day 9 and 3, respectively; showed a differential distribution. Spontaneous EV-CAL-62/Rluc shown distributed mostly to lung followed by liver, spleen & kidney. The new BLI system used to show spontaneous distribution of EV-CAL-62/Rluc in subcutaneous CAL-62/Rluc bearing mice. Dye (DiR)-labeled EV-CAL-62/Rluc showed a different distribution in vivo & ex vivo compared to EV-CAL-62/Rluc. Fluorescent signals were predominately detected in the liver ( P < 0.05) and spleen ( P < 0.05) regions. The bioluminescent EVs developed in this study may be used for monitoring of EVs in vivo . This novel reporter-imaging approach to visualization of EVs in real time is expected to pave the way for monitoring of EVs in EV-based treatments.
No takes yet. Share an insight, caveat, or question.
Gangadaran et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: