Answers are grounded in this paper and cite their sources.
Owing to the inherent characteristics of grid‐side inverters, a minimum dc‐side voltage limit usually exists in grid‐connected inverters. To solve this problem, this study proposes a convenient method of designing a novel LCL circuit for a grid‐connected inverter, based on an LCL filter. The primary goal is to reduce the minimum dc‐side voltage limit, while maintaining a considerably low harmonic content in the grid‐side current. The design example of a photovoltaic grid‐connected system demonstrates the convenience of the novel LCL circuit design, and the validity and effectiveness of the novel LCL circuit are verified by simulation and experiments.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: