The introduction of an efficient signal intensity flip device to construct a dual-wavelength ratiometric electrochemiluminescence (ECL) system is of great significance for the trace detection of target analytes. In this work, a dual-wavelength ratiometric ECL sensor was rationally designed using Zr-MOF as a bidirectional modulation factor, enabling complete reversal of the dual ECL signals at two distinct wavelengths and achieving highly sensitive detection of 5F-ADB. Specifically, Zr-MOF acts as a coreaction promoter to accelerate the decomposition of K 2 S 2 O 8, thereby significantly enhancing the cathodic ECL signal of Tg-CNNSs/CaMoO 4 at 475 nm. In addition, the overlap between the ultraviolet absorption and ECL emission spectra, along with the shortened fluorescence lifetime, confirms that Zr-MOF induces electrochemiluminescence resonance energy transfer (ECL-RET) in Eu-MOFs, resulting in pronounced quenching of the anodic ECL signal at 650 nm. The constructed sensor exhibited outstanding analytical performance, achieving a detection limit as low as 4.06 × 10 –15 g/L through the introduction of a highly complementary dual-aptamer recognition system. Furthermore, satisfactory recovery results in e-cigarette samples demonstrate the practical applicability and reliability of this sensing strategy, providing a new direction for the development of high-performance biosensors and drug-monitoring devices.