Answers are grounded in this paper and cite their sources.
The ratio of horizontal to vertical permeability may be determined by analysis of drawdown data from piezometers or partially penetrating observation wells near a partially penetrating production well. The analyses are made by comparing measured drawdowns in the piezometers to those predicted if the production well fully penetrated the aquifer. The differences between the measured and predicted drawdowns are determined, and the distances from the pumped well at which these differences would occur in an isotropic aquifer are determined from an equation. The permeability ratio is computed as the square of the ratio of actual distances to computed distances. The ratio of horizontal to vertical permeability in glacial outwash in central Wisconsin was determined from 5 aquifer tests to range from about 2 to about 20.
No takes yet. Share an insight, caveat, or question.
Edwin P. Weeks (1969) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: