This paper documents fatigue-related mechanical failures in variable-frequency drive (VFD) motor machinery due to mechanical vibrations excited by drive torque harmonics which are created by pulse width modulation (PWM) switching. Present effort models the coupled system with a full electrical system (including the rectifier, dc bus, inverter, and motor), and an industrial mechanical system (including flexible couplings, gearboxes, and multiple inertias). The models are formed by a novel combination of a commercial motor code with a general self-written mechanical code. The approach extends failure prediction beyond the simple occurrence of resonance to fatigue life evaluation based on the rain-flow algorithm, which is suitable for both steady state and transient start-up mechanical response. The second contribution is a demonstration that the common use of a multilevel inverter to reduce voltage/current harmonics may actually exacerbate resonance and fatigue failure. This is shown to be caused by a resulting amplitude increase of torque components in proximity to potential resonance frequencies.
No takes yet. Share an insight, caveat, or question.
Han et al. (2013) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: