Key result
In a pig model, spinal cord blood flow decreased significantly during aortic arch surgery, but changes were comparable between the frozen and conventional elephant trunk techniques.
Why the study?
Does the frozen elephant trunk technique compared to conventional elephant trunk affect spinal cord blood flow in a pig model of aortic arch surgery?
Does the frozen elephant trunk technique compared to conventional elephant trunk affect spinal cord blood flow in a pig model of aortic arch surgery?
Absolute Event Rate: 0.05% vs 0.02%
p-value: p=0.047
In a pig model, the frozen elephant trunk technique did not adversely affect spinal cord blood flow or increase ischemic damage compared to the conventional technique.
Comparable perfusion in pigs suggests no added ischemic risk with frozen technique; hypothesis-generating for human aortic arch repair.
OBJECTIVES: The treatment of patients with extensive thoracic aortic disease involving the arch and descending aorta is often performed using the frozen elephant trunk technique (FET). Spinal cord blood flow (SCBF) in cervical, thoracic and lumbar sections prior, during and after aortic arch surgery were compared in conventional elephant trunk (cET) and FET technique in a pig model. METHODS: German Landrace pigs (75-85 kg) underwent aortic arch surgery using the FET (n = 8) or cET (n = 8) techniques. The E-vita Open hybrid stent graft was applied in all FET animals. Regional SCBF was measured 4 times: (i) before cardiopulmonary bypass, (ii) after 1 h, (iii) after 3 h, and (iv) after 6 h of reperfusion using fluorescence microspheres. Spinal cord segments were examined histopathologically and by immunohistochemistry. RESULTS: SCBF in FET decreased significantly from 0.13 ± 0.03 to 0.05 ± 0.02 ml/min/g after 1 h (P = 0.047). While at 3 h of reperfusion, SCBF increased and was comparable to baseline (0.09 ± 0.01 ml/min/g), beyond this time SCBF decreased again (0.05 ± 0.02 ml/min/g). A similar trend was found for SCBF in the cET group (baseline: 0.16 ± 0.04 ml/min/g, 1 h reperfusion: 0.02 ± 0.01 ml/min/g, 3 h reperfusion: 0.03 ± 0.01 ml/min/g and 6 h reperfusion: 0.02 ± 0.01 ml/min/g, P = 0.019). Cervical, thoracic and lumbar SCBF were also comparable in both groups. Histological analyses of spinal cord showed no differences in necrosis between cET and FET, while no differences were found for hypoxia-inducible factor-1α and apoptosis-inducing factor. In contrast, oxidative stress and caspase-induced apoptosis were higher in cET versus FET. CONCLUSIONS: The SCBF changed significantly during extensive aortic arch surgery with circulatory arrest and moderate hypothermia, but such changes were comparable between the FET and cET groups. The implantation of hybrid stent graft did not influence SCBF in thoracic and lumbar segments of the spinal cord. The immunohistological examination showed no differences between cET and FET regarding ischaemic damage and hypoxia-induced effects in spinal cord segments.
No takes yet. Share an insight, caveat, or question.
Leontyev et al. (2017) studied Extensive thoracic aortic disease (animal model) (n=16). Frozen elephant trunk (FET) technique vs. Conventional elephant trunk (cET) technique was evaluated on Spinal cord blood flow (SCBF) after 1 h of reperfusion (p=0.047). In a pig model, spinal cord blood flow decreased significantly during aortic arch surgery, but changes were comparable between the frozen and conventional elephant trunk techniques.