Answers are grounded in this paper and cite their sources.
We present a compact L-band orthomode transducer (OMT) with a new waveguide junction consisting of a quad-ridged square waveguide and four single-ridged triangular waveguides. Quad-ridged square and single-ridged triangular waveguides of various sizes were numerically analyzed to estimate the cutoff frequencies and characteristic impedances of the waveguides. An optimum junction structure for the OMT with a low cutoff frequency and specific characteristic impedance was found based on the numerical simulation. The junction has a relatively small size without waveguide branches, and provides good impedance matching with a 50 Ω coaxial feed line. In addition, Klopfenstein and linear tapers were employed to design waveguide ridges for minimizing mismatches at the OMT junction. Measurement showed a bandwidth of about 400 MHz from 1.0 to 1.4 GHz and an isolation level below -40 dB in the frequency range. The cross section of the OMT was reduced to 62% of the standard waveguide cross section, and the total length is only 56 cm (2.24 λ0) at 1.2 GHz.
No takes yet. Share an insight, caveat, or question.
Hwang et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: