Key result
TTE shows ~88% agreement with TOE in determining M-TEER anatomical suitability for severe MR.
Why the study?
In patients with significant MR undergoing M-TEER, TTE is the initial diagnostic tool while TOE provides better anatomical details. Whether TTE is as effective as TOE in selecting patients with severe MR eligible for M-TEER needed to be assessed.
Does transthoracic echocardiography (TTE) correlate and agree sufficiently with transesophageal echocardiography (TOE) to serve as an alternative pre-procedural screening modality for M-TEER eligibility in patients with severe mitral regurgitation?
Cohort (n=40)
Independent evaluation by two dedicated cardiologists (one for TTE, one for TOE)
No
Does transthoracic echocardiography (TTE) correlate and agree sufficiently with transesophageal echocardiography (TOE) to serve as an alternative pre-procedural screening modality for M-TEER eligibility in patients with severe mitral regurgitation?
2D/3D TTE demonstrates strong correlation and moderate-to-high agreement with TOE for pre-procedural M-TEER anatomical screening, suggesting it may serve as a non-invasive initial screening alternative in patients with uncomplicated functional MR at high-volume centers.
Answers are grounded in this paper and cite their sources.
TTE may support initial non-invasive screening for M-TEER eligibility; leaves open whether it can replace TOE in routine practice.
BACKGROUND: In patients with significant mitral regurgitation (MR) undergoing transcatheter edge-to-edge repair (M-TEER), assessment of mitral valve (MV) anatomy is essential. While transthoracic echocardiography (TTE) is the initial diagnostic tool, transesophageal echocardiography (TOE) provides better anatomical details. The study aims to assess whether TTE is as effective as TOE in selecting patients with severe MR who are eligible for M-TEER. METHODS: From January to December 2024, patients with severe MR eligible for TEER were enrolled at the Fondazione Monasterio Heart Hospital, Italy. They underwent a comprehensive TTE and TOE examination. Cardiologists assessed the severity of MR and valve anatomy using specific protocols. Measurements included MV area, MV gradient, posterior leaflet length, fossa ovalis high, presence of fails, clefts, and calcifications. Three levels of anatomic complexity were defined to determine eligibility for TEER. RESULTS: The study includes 40 patients with severe MR. The correlation between TTE and TOE for key parameters was strong, with coefficients ranging from 0.734 to 0.901, indicating high agreement between the two methods. The comparison of categorical features showed high agreement between TTE and TOE in detecting critical MV conditions, with kappa values ranging from 0.717 to 0.930. The agreement for classifying patients as suitable for M-TEER was 87.5%, indicating moderate consistency between the two methods. CONCLUSIONS: TTE may be a viable alternative to TOE for assessing MV anatomy and function before M-TEER in MR patients, especially in high-volume centers. While TTE strongly correlated with TOE for most parameters, TOE was superior for some features. Further research is needed to refine the clinical application of TTE and to define patient selection criteria for its use as the primary imaging modality for pre-procedural M-TEER screening.
No takes yet. Share an insight, caveat, or question.
Bonanni et al. (2025) conducted a cohort in Severe mitral regurgitation eligible for transcatheter edge-to-edge mitral valve repair (M-TEER) (n=40). 2D and 3D Transthoracic Echocardiography (TTE) vs. 2D and 3D Transesophageal Echocardiography (TOE) was evaluated on Agreement between TTE and TOE in classifying anatomical complexity and suitability for M-TEER (Observed agreement 87.5%, Cohen's Kappa 0.546, p=<0.0001). Transthoracic echocardiography showed 87.5% agreement with transesophageal echocardiography in classifying severe MR patients as suitable for M-TEER.
Synapse has enriched 10 related papers. Consider them for comparative context: