Answers are grounded in this paper and cite their sources.
The cooling performance of the impingent/effusion structure on the pressure side of nozzle guide vanes tested in an engine operating for the various duration of 100 h, 300 h, and 500 h was evaluated in this study via infrared thermal imaging. The original vane was also examined as a comparison. The examined impingement/effusion structure consisted of 4 rows of impinging hole and 5 rows of film hole. The tested coolant-to-mainstream mass flow ratios was 0.0392–0.0784. Reynolds number was 624000 based on the vane chord and cascade inlet velocity. Cooling performance degradation in the impingent/effusion structure was investigated as it relates to oxidation and dust deposition after various durations of engine operation. The two-dimensional temperature distributions in the vane wall became nonuniform over time. The cooling performance quickly degraded after the vane was tested for 100 h in the engine; this degradation grew less intense as operation duration continually increased. The surface-averaged values of the overall cooling effectiveness of the impingent/effusion structure decreased by 9%–11% dependent on the mass flow ratio after the vane was tested for 500 h of engine operation. The coolant flow resistance increased with engine operation time as well.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: