Key result
Non-invasive cardiac scale measurements of stroke volume and cardiac output strongly correlated with the gold-standard direct Fick method.
Why the study?
Objective markers of cardiac function are limited in the outpatient setting but may be beneficial for monitoring patients with chronic cardiac conditions.
Does a non-invasive scale accurately measure stroke volume and cardiac output compared to the direct Fick method in patients with unexplained dyspnea?
Observational (n=32)
No
Does a non-invasive scale accurately measure stroke volume and cardiac output compared to the direct Fick method in patients with unexplained dyspnea?
Answers are grounded in this paper and cite their sources.
A novel non-invasive scale accurately estimates stroke volume and cardiac output compared to the direct Fick method, offering a potential tool for longitudinal outpatient monitoring.
Background Objective markers of cardiac function are limited in the outpatient setting and may be beneficial for monitoring patients with chronic cardiac conditions. Objective We assess the accuracy of a scale, with the ability to capture ballistocardiography, electrocardiography, and impedance plethysmography signals from a patient’s feet while standing on the scale, in measuring stroke volume and cardiac output compared to the gold-standard direct Fick method. Methods Thirty-two patients with unexplained dyspnea undergoing level 3 invasive cardiopulmonary exercise test at a tertiary medical center were included in the final analysis. We obtained scale and direct Fick measurements of stroke volume and cardiac output before and immediately after invasive cardiopulmonary exercise test. Results Stroke volume and cardiac output from a cardiac scale and the direct Fick method correlated with r = 0.81 and r = 0.85, respectively (P < 0.001 each). The mean absolute error of the scale estimated stroke volume was -1.58 mL, with a 95% limits of agreement (LOA) of -21.97 mL to 18.81 mL. The mean error for the scale estimated cardiac output was -0.31 L/min, with a 95% LOA of -2.62 L/min to 2.00 L/min. The change in stroke volume and cardiac output before and after exercise were 78.9% and 96.7% concordant, respectively between the two measuring methods. Conclusions This novel scale with cardiac monitoring abilities may allow for non-invasive, longitudinal measures of cardiac function. Using the widely accepted form factor of a bathroom scale, this method of monitoring can be easily integrated into a patient’s lifestyle.
No takes yet. Share an insight, caveat, or question.
Yazdi et al. (2021) conducted an observational in Unexplained dyspnea (n=32). Bodyport Cardiac Scale vs. Direct Fick method was evaluated on Correlation of stroke volume and cardiac output measurements between the cardiac scale and direct Fick method (r = 0.81 for stroke volume, r = 0.85 for cardiac output, p=<0.001). Non-invasive cardiac scale measurements of stroke volume and cardiac output strongly correlated with the gold-standard direct Fick method.