Key result
Heart dosimetry parameters (V5, V10, V20, and mean heart dose) were independently and positively associated with an elevated sST-2 change rate during chest radiotherapy (all P < .05).
Why the study?
Early screening and diagnosis of radiation-induced heart disease is difficult in patients with chest radiation exposure, and the relationship between heart dose parameters and sST-2 changes was unknown.
Do heart dosimetry parameters correlate with changes in the cardiac biomarker sST-2 in patients receiving chest radiation for thoracic cancer?
Cohort (n=60)
Do heart dosimetry parameters correlate with changes in the cardiac biomarker sST-2 in patients receiving chest radiation for thoracic cancer?
Effect estimate: β = 0.04 to 0.10
p-value: p=<.05
Higher radiation doses to the heart during thoracic radiotherapy are independently associated with greater increases in the cardiac biomarker sST-2, suggesting early myocardial stress.
Heart dosimetry parameters were associated with sST-2 rises after thoracic radiotherapy; hypothesis-generating and requires prospective validation before practice change.
Background Early screening and diagnosis of radiation‐induced heart disease (RIHD) is difficult in patients with chest radiation exposure. sST‐2 is involved in myocardial stress or injury. We evaluated the relationship between heart dose parameters and sST‐2 changes in chest malignant tumor patients who received chest radiation. Methods We prospectively collected thoracic malignancy cancer patients who had received chest radiotherapy. Heart dosimetry parameters were extracted from the treatment planning system. sST‐2 was measured at baseline, the middle stage, and after radiotherapy (recorded as pre‐ST‐2, mid‐ST‐2, and post‐ST‐2). sST‐2 change rate was calculated. Scatter plots showed the relationship between cardiac dose parameters and ST‐2 change rate. Multiple regression was used to analyze the relationship between cardiac dose parameters and ST‐2 change rate. Results Totally, 60 patients were enrolled. The mean V 5 , V 10 , V 20 , V 30 , V 40 , and MHD was 60.93 ± 27.79%, 51.43 ± 25.44%, 39.17 ± 21.75%, 28.07 ± 17.15%,18.66 ± 12.18%, and 18.60 ± 8.63 Gy, respectively. The median M‐LAD was 11.31 (IQR 3.33‐18.76) Gy. The mean pre‐ST‐2, mid‐ST‐2, and post‐ST‐2 was 5.1 ± 3.8, 6.4 ± 3.9, and 7.6 ± 4.4, respectively. sST‐2 was elevated with thoracic irradiation ( P < .001). Multivariate linear regression analyses showed that V 5 , V 10 , V 20 , and MHD were independently and positively associated with ST‐2 change rate ( β = .04, .04, .04, and .10, respectively, all P < .05). Conclusion Serum sST‐2 levels were elevated over time during radiotherapy. V 5 , V 10 , V 20 and MHD were independently and positively associated with the elevated ST‐2 change rate.
No takes yet. Share an insight, caveat, or question.
Zeng et al. (2020) conducted a cohort in Thoracic malignancy (n=60). Heart dosimetry parameters (chest radiation) was evaluated on sST-2 change rate (β = 0.04 to 0.10, p=<.05). Heart dosimetry parameters (V5, V10, V20, and mean heart dose) were independently and positively associated with an elevated sST-2 change rate during chest radiotherapy (all P < .05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: