This is the authors' abstract. We don't add key points for this paper.
Incorporating subsynchronous damping controllers (SSDCs) into the control loops of doubly-fed induction generators (DFIGs) is one of the most cost-effective methods to suppress subsynchronous oscillation (SSO). However, it is difficult to achieve satisfactory control performance of SSDCs due to the time-varying structure and operating conditions of wind integrated power systems. In this paper, an improved model-free adaptive control (MFAC) method is developed for DFIGs to overcome the limitations of conventional methods for SSO mitigation. First, the structure of the MFAC-based SSDC (M-SSDC) for DFIGs is designed. Then, an improved MFAC predictive control algorithm is proposed to achieve SSO mitigation. Moreover, the stability of the closed-loop system with the proposed M-SSDC is analyzed, which provides some guidelines for determining controller parameters. Additionally, the input-output signal pair of M-SSDC is selected by using geometric measure for the optimum damping performance. Case studies under various operating conditions of the test power system validate the effectiveness of the proposed M-SSDC as well as its superior damping performance over conventional approaches.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: