Observational (n=165)
Absolute Event Rate: 26.4% vs 32.1%
p-value: p=<10^-15
A novel outlier-resilient complexity analysis method for heartbeat dynamics can detect cardiac control degradation and predict mortality in critically ill patients.
Should not yet alter practice in HF or ECMO; leaves open prospective validation of this outlier-resilient metric.
Complexity in physiological outputs is believed to be a hallmark of healthy physiological control. How to accurately quantify the degree of complexity in physiological signals with outliers remains a major barrier for translating this novel concept of nonlinear dynamic theory to clinical practice. Here we propose a new approach to estimate the complexity in a signal by analyzing the irregularity of the sign time series of its coarse-grained time series at different time scales. Using surrogate data, we show that the method can reliably assess the complexity in noisy data while being highly resilient to outliers. We further apply this method to the analysis of human heartbeat recordings. Without removing any outliers due to ectopic beats, the method is able to detect a degradation of cardiac control in patients with congestive heart failure and a more degradation in critically ill patients whose life continuation relies on extracorporeal membrane oxygenator (ECMO). Moreover, the derived complexity measures can predict the mortality of ECMO patients. These results indicate that the proposed method may serve as a promising tool for monitoring cardiac function of patients in clinical settings.
No takes yet. Share an insight, caveat, or question.
Lo et al. (2015) conducted an observational in Congestive heart failure and critical illness requiring ECMO (n=165). Multiscale symbolic entropy analysis (MSSE) vs. Traditional multiscale entropy (MSE) / Healthy controls was evaluated on Symbolic sample entropy (eEC) at scales 1-5 (p=<10^-15).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: