Answers are grounded in this paper and cite their sources.
A highly sensitive real‐time ion‐assisted OH measurement technique has recently been developed and tested. It offers an OH detection sensitivity of about 1×10 5 molecules/cm 3 with a 300‐s integration time and provides useful OH concentration measurements on a 10‐s time scale. Measurements of OH concentration are seen to track solar flux during both short and long periods of cloudiness. Good temporal correspondence between changes in OH and O 3 concentration as differing air masses pass the measurement site are also observed and discussed. The present technique provides a new opportunity for fast sensitive OH measurement using a totally new nonoptical measurement scheme.
No takes yet. Share an insight, caveat, or question.
Eisele et al. (1991) studied this question.