This is the authors' abstract. We don't add key points for this paper.
Accurate ultrasound imaging of internal defects plays a crucial role in evaluating the performance and safety of concrete structures. However, high-quality imaging remains a significant challenge due to material characteristics such as anisotropy, high attenuation, and scattering. In this study, a modified Total Focusing imaging Method (TFM) is proposed by introducing a delay-multiply-and-sum (DMAS) beamforming algorithm into TFM. This method incorporates the spatial coherence of different received signals and additional signal information to effectively improve imaging quality. Meanwhile, a dynamic apodization factor is introduced to suppress beam sidelobes, further enhancing the imaging quality. Hence, the proposed method is named Apodization DMAS-TFM. Numerical simulations and experiments on concrete are conducted, and the results show that the Apodization DMAS-TFM method improves the signal-to-noise ratio of images by 119.14 % in simulations and 72.79 % in experiments compared to TFM. The lateral resolution and contrast ratio are also improved, which is beneficial for identifying defects inside concrete, especially small-sized defects located at relatively deep positions. Meanwhile, the computation time is not significantly increased compared to TFM. Therefore, the Apodization DMAS-TFM method shows considerable potential for the in-situ detection of defects in concrete structures.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: