The as-produced isomer mixture of the organic photovoltaic device acceptor material bis-[60]PCBM has been purified into its constituents by peak-recycling HPLC, and those individual isomers were characterised by UV-Vis absorption spectroscopy and cyclic voltammetry. A total of 18 isomers were purified from the mixture to a standard exceeding 99.5% with respect to other isomers. The HOMOs, LUMOs, and HOMO-LUMO gaps of the purified isomers vary from -5.673 to -5.444 eV, -3.901 to -3.729 eV, and 1.664 to 1.883 eV, respectively. We also find a correlation between HPLC retention time and the relative positions of the addends; in that generally the closer the addends are to each other the longer the retention time of the isomer, and vice versa.
No takes yet. Share an insight, caveat, or question.
Shi et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: