Key result
The RIONI study is designed to validate whether compressed intracardiac electrograms transmitted daily via home monitoring are equivalent to complete stored Holter electrograms for evaluating ICD therapy.
Why the study?
Does IEGM-online based evaluation provide equivalent diagnostic accuracy to complete ICD episode Holter evaluation for assessing ICD therapeutic decisions?
Does IEGM-online based evaluation provide equivalent diagnostic accuracy to complete ICD episode Holter evaluation for assessing ICD therapeutic decisions?
The RIONI study is designed to validate the diagnostic equivalence of compressed IEGMs transmitted daily via home monitoring compared to complete stored ICD episode Holters.
Answers are grounded in this paper and cite their sources.
Equivalence of daily compressed IEGMs to full Holter for ICD decisions remains unproven; RIONI will test this prospectively.
Appropriate and inappropriate therapies of implantable cardioverter defibrillators (ICDs) have a major impact on morbidity and quality of life in ICD recipients. The recently introduced home monitoring of ICD devices is a promising new technique which remotely offers information about the status of the system. Stored intracardiac electrograms (IEGMs), which are essential for correct classification of appropriate and inappropriate ICD discharges, have until now not been available with ICD home monitoring on a day-by-day basis because of limitations of transferable data. We demonstrate the first compressed IEGMs daily transferable via home monitoring (IEGM-online). Validation of these electrograms will be performed in the Reliability of IEGM-Online Interpretation (RIONI) study. A total of 210 episodes of stored IEGMs will be collected by at least 12 European centres. The primary endpoint of this study is to investigate whether the IEGM-online based evaluation of the appropriateness of the ICDs therapeutic decision following episode detection is equivalent to the evaluation based on the complete ICD episode Holter extracted from the IEGM stored. The evaluation is independently done by an expert board of three experienced ICD investigators. The equivalence of the two methods is accepted if the evaluations yield a different conclusion for <10% of all evaluated IEGMs. The conclusion of the study is expected at the beginning of 2007. If RIONI successfully validates IEGMs transmitted via home monitoring, a strong basis for the use of this promising technique will be established.
No takes yet. Share an insight, caveat, or question.
Perings et al. (2006) studied Patients with implantable cardioverter defibrillators (ICDs). IEGM-online based evaluation via home monitoring vs. Evaluation based on the complete ICD episode Holter was evaluated on Equivalence of the IEGM-online based evaluation of the appropriateness of the ICDs therapeutic decision compared to the complete ICD episode Holter. The RIONI study is designed to validate whether compressed intracardiac electrograms transmitted daily via home monitoring are equivalent to complete stored Holter electrograms for evaluating ICD therapy.