Answers are grounded in this paper and cite their sources.
Using commercially available broad beam ion sources and power supplies a tunable electronic beam switch was designed to generate a pulsed ion beam. The developed switch triggers all ion source supply voltages of a continuously powered electron cyclotron resonance ion source. Frequencies ranging from 50 Hz to 10 kHz and a duty cycle adjustable between 0.1 and 0.9 can be selected by the electronic switch. This results in ion beam pulse lengths ranging from 10 μs to 18 ms. Important properties of the pulsed ion beam were investigated by integrated and time-resolved measurements of the ion current density and the energy influx. Thereby, the rise and fall times of the ion beam current density were determined to be 9 μs and 2.5 μs, respectively. There are manifold applications of an electronic beam switch triggering an ion beam. As an example, the GaAs sputter process has been investigated to verify the electrical measurements of the pulsed ion beam.
No takes yet. Share an insight, caveat, or question.
Dienelt et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: